Micos VSD Screw compressor is the optimal choice for reducing energy cost.
Micos VSD compressor changes drive motor’s rotation speed to produce only the necessary amount according to actual demand of compressed air. It eliminates unload operation and frequent restart of compressor and consistent discharge pressure provides energy saving up to 30% of total energy expense..
Article | Unit | Micos 22V | Micos 37V | Micos 55V | Micos 75V | Micos 110V | Micos 150V | ||
---|---|---|---|---|---|---|---|---|---|
Compression method | - | Oil flooded, 1-stage compression | |||||||
Capacity (F.A.D)(1) |
7 bar | ㎥/min | 1.8~3.90 | 2.0~6.7 | 3.1~10.3 | 4.1~13.7 | 6.4~21.2 | 8.3~28.5 | |
9bar | 1.0~3.6 | 1.8~6.1 | 2.6~9.10 | 3.6~13.1 | 5.1~18.6 | 7.0~26.1 | |||
12bar | - | 1.4~4.6 | 2.1~7.1 | 2.9~9.8 | 3.8~16.1 | 5.9~23.0 | |||
Compression Unit | Driven method | - | Direct coupled & Variable speed drive | ||||||
Suction Temperature(3) | ℃ | MAX. 40 | |||||||
Outlet Temperature | MAX. Suction temperature + 15 | ||||||||
Cooling method | - | Air cooled | |||||||
Motors | Rated power | kW | 22 | 37 | 55 | 75 | 110 | 160 | |
Input voltage | V | AC 220 / 380 / 440, 3Phase | AC 380 / 440, 3 Phase | ||||||
Frequency | Hz | 50 / 60 | |||||||
Starting method | - | Soft start by Inverter(No peak current) | |||||||
Pipe connection | - | 25A | 32A | 50A | 65A | ||||
Control method | - | Micos-Ⅳ Micom controller | |||||||
Noise level(2) | db(A) | 65 | 68 | 70 | 71 | 73 | 76 | ||
Weight | kg | 670 | 1,160 | 1,850 | 2,040 | 2,680 | 3,320 | ||
Dimension (L X B X H) | mm | 1,380×880×1,348 | 1,700×1,065×1,500 | 1,900x1,330x1,750 | 2,482×1,800×1,960 |
Article | Unit | Micos 190V | Micos 225V | Micos 260V | Micos 300V | ||
---|---|---|---|---|---|---|---|
Compression method | - | Oil flooded, 1-stage compression | |||||
Capacity (F.A.D)(1) |
7 bar | ㎥/min | 10.5~35.0 | 12.1~40.6 | 13.5~45.8 | 17.7~55.3 | |
9bar | 8.7~30.0 | 9.8~33.3 | 11.0~38.2 | 15.8~50.2 | |||
12bar | 7.3~26.8 | 8.1~29.6 | 9.1~31.9 | 13.8~45.0 | |||
Compression Unit | Driven method | - | Direct coupled & Variable speed drive | ||||
Suction Temperature(3) | ℃ | MAX. 40 | |||||
Outlet Temperature | MAX. Suction temperature + 15 | ||||||
Cooling method | - | Air cooled | |||||
Motors | Rated power | kW | 190 | 225 | 260 | 315 | |
Input voltage | V | AC 220 / 380 / 440, 3상 | |||||
Frequency | Hz | 50 / 60 | |||||
Starting method | - | Soft start by Inverter(No peak current) | |||||
Pipe connection | - | 80A | 100A | ||||
Control method | - | Micos-Ⅳ Micom controller | |||||
Noise level(2) | db(A) | 78 | 79 | 81 | 83 | ||
Weight | kg | 4,910 | 6,260 | 6,590 | 7,500 | ||
Dimension (L X B X H) | mm | 3,382×2,100×2,500 | 3,382×2,100×2,500 (800×1,080×2,500) |
Micos-Ⅳ controller detects system pressure and controls inverter to produce exact quantity of air according to the factory’s air demand. So it can save energy cost by reducing the unloading action of other compressors.
Micos series VSD compressors have direct coupled driven method without acceleration gear box. So they can reduce the transmission loss caused by the gear box and can guarantee high energy efficiency, low maintenance cost and quite operation.
CE & UL certified inverter is adapted all models of VSD compressor. The electric cabinet is fully separated from mechanical component and exclusive cooling fan and pre-filter are installed in the cabinet, So MICOS VSD compressor can be operated safely at any industrial surroundings.