Malfunction
Phenomenon
|
Expected Cause |
Countermeasure |
Initial Operation Defect |
Main Motor Overload |
- 1.Check and adjust current set value of overload relay.
- 2.Check rotation status of load axle, and if defect, contact place of purchase or our company for after service.
|
Fan Motor Overload |
- 1.Check and adjust current set value of heat radiation overload relay.
- 2.Check cooler pollution status and if polluted, remove dirt and clean.
- 3.Check rotation status of load axle, and if defect, contact place of purchase or our company for after service.
|
Pressure Switch Error |
- 1.Check intake piping status and the set pressure and pressure difference and adjust.
- 2.If pressure switch is damaged or is defect, contact place of purchase or our company for after service.
|
Discharge Temperature Overheat |
- 1.Improve installation environment and maintain surrounding temperature below 40℃.
- 2.Check cooling fan direction, status and if cooler is polluted, clean.
- 3.Refil or replace oil and replace oil filter.
- 4.Replace oil separator filter.
- 5.Dismantle oil recovery (scavenge) line and clean.
- 6.If temperature switch and relay is defect, contact place or purchase or our company for after service.
|
Electric Circuit Error |
- 1.Check status of wire and disconnection according to the control circuit drawing and check bolt tightness.
- 2.If part defect, contact place of purchase or our company for
After service.
|
Power Specification
Defect
|
- 1.Usage by applying appropriate power specification.
|
Stop or Alarm ringing during Operation |
Main Motor Overload |
- 1.Check and adjust current set value of overload relay.
- 2.Check rotation status of load axle, and if defect, contact place of purchase or our company for after service.
|
Fan Motor Overload |
- 1.Check and adjust current set value of heat radiation overload relay.
- 2.Check cooler pollution status and if polluted, remove dirt and clean.
- 3.Check rotation status of load axle, and if defect, contact place of purchase or our company for after service.
|
Discharge Temperature Overheat |
- 1.Improve installation environment and maintain surrounding temperature below 40℃.
- 2.Check cooling fan direction, status and if cooler is polluted, clean.
- 3.Refil or replace oil and replace oil filter.
- 4.Replace oil separator filter.
- 5.Dismantle oil recovery (scavenge) line and clean.
- 6.If temperature switch and relay is defect, contact place or purchase or our company for after service.
|
Noise and vibration during operation |
Rotation Part Error |
- ,
1.If rotation part such as motor or air end is defect, contact place of purchase or our company for after service.
|
Surrounding Environment Defect |
- 1.Re-operate after improving surrounding environment.
|
Lock/Tightness Status Defect |
- 1.Check cover locking, parts tightness, bolt tightness status.
|
Pressure increase, decrease, defect during operation |
Pressure Switch Error |
- 1.Check intake piping status and the set pressure and pressure difference and adjust.
- 2.If pressure switch is damaged or is defect, contact place of purchase or our company for after service.
|
Solenoid Valve Error |
- 1.If solenoid valve operation is defect, contact place of purchase or our company for after service.
- 2. Check status of wire and disconnection according to the control circuit drawing and check bolt tightness..
|
Safety Valve Error |
- 1.If safety valve operation is defect, contact place of purchase or our company for after service.
|
Electric Circuit Error |
- 1.Check status of wire and disconnection according to the control circuit drawing and check bolt tightness.
- 2.If part defect, contact place of purchase or our company for
After service.
|
Air Filter Error |
- 1.If air filter is polluted, replace it.
|
Intake Valve Error |
- 1.If intake valve operation is defect, contact place of purchase
Or our company for after service.
|
Pressure Switch Error |
- 1.Check intake piping status and the set pressure and pressure difference and adjust.
- 2.If pressure switch is damaged or is defect, contact place of purchase or our company for after service.
|
Leakage |
- 1.After checking leakage part, tighten parts.
- 2.If part is defect, contact place of purchase or our company
For after service.
|